Product Data Sheet Edition 11.08.2015 Sikagard 307 W Sikagard 307 W Industrial Flooring Single component waterborne modified acrylicpolyurethane dispersion based surface coating with a gloss finish Description Sikagard 307 W is a single component waterborne polyurethane based coating designed with specific hygiene functionality. The in film preservation is designed to remain permanently locked in and active ensuring no growth of surface micro-organisms on the Sikagard 307 W. Sikagard 307 W is available in white. Custom colors required 10 to 15 business days lead time. Where to Use Advantages Internal walls and ceilings of environments that require continuously sanitary conditions. Pharmaceutical Food Beverage Bio-tech manufacturing Hospitals Clean rooms Laboratories Single component waterbased low odor Hard finish and impact scratch and abrasion resistant Gloss easy clean finish Non-yellowing Fast development of physical strength Rapid drying same day re-coat if necessary One coat finish airless spray Leach resistant in film preservative Chemical Resistance Standard 10 solutions of acids and alkalis including Nitric Acid AND Caustic Soda failed to cause breakdown of the Sikagard 307 W. Typical Data Chemical Base VOC Content Water Vapor Transmission Fire Retardancy Accelerated Weathering Waterborne acrylicpolyurethane copolymer dispersion 0.22 lbgal. or 81.7 gl perms 4 mil DFT Excellent resistance to surface spread of flame. ASTM G53-88- 5000 hours Q.U.V. B lamps no discoloration chalking or crazing. Slight loss of gloss. Tensile Elongation BS EN ISO 527-3-Unreinforced 24 hours - maximum stress tensile load at break 6.8 Nmm or 987 psi elongation at break 110 48 hours - maximum stress tensile load at break 7.2 Nmm or 1045 psi elongation at break 87 72 hours - maximum stress tensile load at break 13.2 Nmm or 1920 psi elongation at break 50 Adhesion Tensile Strength Density Hardness Persoz Solids Content Gloss Opacity Contrast Ratio Resistance

to QUV Surface Granularity Abrasion Resistance Scratch Resistance Packaging Shelf Life Storage Conditions Coarse Concrete 261 psi 1.8 MPa Nmm2 Smooth Concrete 754 psi 5.2 MPa Nmm Brick 551 psi 3.8 MPa Nmm Cement cladding board 174 psi 1.2 MPa Nmm Steel 710 psi 4.9 MPa Nmm 2326 psi 16 Nmm BS EN ISO 527-3 Unreinforced 10.43 lbs per gallon 1.26 kgl DIN EN ISO 2811-1 125 49 by weight and 36 by volume. 60 gloss units at 60 degree Classified as gloss to BS EN 133002001 99.5 130 micron film Classified as Class 1 to BS EN 133002001 No appreciable change other than a minor reduction in gloss. ASTM G154-042500 hours QUV-B 0.01 mm Classified as fine to BS EN 133002001 113 mg weight loss ASTM D 4060 CS10 Wheel 1000 g load Short cure overnight slight penetration at 2000 grams longer cure 7 days penetration at 3000 grams surface marking evident. 5 gallon pails 24 months when stored under the recommended conditions. 50F 10C to 90F 32C How to Use Surface The substrate must be sound clean dry and free of all contaminants such as dirt oil laitance mold grease and surface treatments. Remove loose material mechanically or high pressure washing. All surfaces to be coated should be clean and free from dampness. Prefill any static cracks with a proprietary flexible latexacrylic caulk. Consult Sika Technical Service. Industrial Flooring New Drywall Minimum level 4 finish prime with Sika Bonding Primer thinned 10 with water. Note 307 W cannot be applied directly over Sika Bonding Primer. An intermediate coat of Sikagard 203 W is required at 6-8 mils. Painted Surfaces Always ensure that the existing paint is fully adhered and sound. Abrade surface using 100 grit screen or paper. Epoxy paints bitumen paints must be abraded using 100 grit and primed using Sika Bonding Primer followed by a 6-8 mil coat of Sikagard 203 W. All painted surfaces that are abraded require cleaning. CMU Block poured in place concrete Spalled flaking or damaged areas should be repaired using compatible materials.

Sikagard 307 W can be used as a primer when diluted with 25 water. Sikagard 203 W can be used as a block filler on new block. Like surfaces that requires a fill parge coat should use Sikagard EpoCem 75 consult product data sheet. Sikagard 307 W can be applied directly to curedsanded EpoCem 75. Cement screeds plaster asbestos cement lining boards For absorbent substrates Sikagard 307 W may be diluted with 25 of clean water as a primer to kill suction. Dustyfriable substrates seal with Sika Bonding Primer and an immediate coat of Sikagard 205 W to stabilize. Concrete Ensure new concrete is at least 10 days preferably 28 days old with moisture content of 20 WME or less. Prime using Sikagard 307 W diluted 25 with water. Wood Damp Free maximum 18 wood moisture equivalent Apply Sikagard 307 W directly. If wood is prone to raised grain then prime with Sikagard 307 W diluted with 25 water when dry lightly sand and apply Sikagard 307 W to correct film thickness. Metals Remove rust to bright metal. Apply Sikalastic Metal Primer WB or Sikalastic Metal Primer use 2 coats on badly pitted or blast prepared surfaces. Non-ferrous metals can be wired brushed to remove oxidation products prime as above. Degrease or use proprietary metal pretreatment fluid on galvanized if greasy. PlasticsInsulation Most plastics can be coated directly. Use Sika Bonding Primer on selfskinning or slab-stock polyurethanepolystyrene foams. Product is not suitable for open fibrous insulation. Dustyfriable substrates require sealing with Sika Bonding Primer and an immediate coat of Sikagard 205 W to stabilize. Mixing Overcoating Sikagard 307 W Clean off all contamination lightly abrade with 100 grit and apply Sikagard 307 W directly. Pre-mix material using a drill and jiffy blade 300-450 rpm Application Rollers - Product may be applied by short to medium 14 - 38 pile synthetic rollers. Two coats are recommended. Rollers are also used during reinforcement embedment. Brushes - A wide soft nylon or bristle b

rush Two coats are recommended ideally product is applied with second coat at 90 to first. Spray Equipment - Most types of industrial airless spray equipment e.g. GRACO ULTRA are suitable pressure 3000 p.s.i. tip size .11 to .15 and 60 fan angle. Although the product is designed with built in flow the finer tip sizes provide the smoothest finish. Tooling Finishing Note All reinforcements using Flexitape and Reemat GFM must use Sikagard 203 W as the base coat. Cure Mechanism 50F60 R.H. Touch dry 45 mins through cure 1 hour. 68F55 R.H. Touch dry 30 mins through cure 45 mins. 86F50-60 R.H. Touch dry 15-20 mins through cure 30-45 mins. Industrial Flooring Application of Sikagard 307 W over Sikagard 307 W Substrate Temp. Minimum Maximum 50F 10C 4 hours 7 days 68F 20C 1 hours 7 days 86F 30C 1 hours 7 days Coverage Application of Sikagard 307 W over Sikagard 203 W Substrate Temp. Minimum Maximum 50F 10C 24 hours 7 days 68F 20C 4 hours 7 days 86F 0C 4 hours 7 days 400 sq.ft.gal. 4 mils WFT recommended 2 coats Limitations Do not apply near foodstuffs in unventilated conditions. Always ensure adequate ventilation. Do not thin or brush out like conventional paints thinning for primer use is permissible. Do not apply the products below a minimum temperature of 40F 4C or a maximum of 90F 32C throughout the application period. Conditions must remain a minimum of 40F 4C and 5F -15C above the dew point. Protect from frost and heat above 90F 32C. Product is not suitable for open fibrous insulation. Sikagard 307 W is normally intended to be used internally however if used externally the natural weathering process of the material may cause slight darkening of the colors and progressive loss of gloss with time. All colors are intermixable. If there is any question as to whether or not the product will adhere to an existing coating or surface a test patch should be applied and evaluated for compatibility and adhesion. Application by roller may result in a slight surface tex

ture when using standard coverage rates. If a smoother finish is required apply 3 thinner coats to achieve desired DFT. Previous coat must be completely dry prior to overcoating. Ensure entire surface is fully dried before proceeding. Crazing may occur when overcoating undried surfaces or when material is applied in a heavy application. Good ventilation is required for Sikagard 307 W to dry properly. Gloss is effected by humidity and temperature. The incorrect assessment and treatment of cracks may lead to a reduced service life and reflective cracking. If additional heating is required do not use gas oil paraffin or other fossil fuel heaters these methods produce large quantities of carbon dioxide and water vapor which may adversely affect the finish. Use only electric powered warm air blower systems. New concrete should be allowed to curehydrate for a minimum of 10 days and preferably 28 days. CAUTION WARNING IRRITANT. Polyurethane Mixture Butyl Carbitol CAS 112-34-5 and N-methyl2-pyrrolidone CAS 872-50-4. Causes eyeskinrespiratory irritation. Harmful if swallowed. WARNING This product contains a chemical known to the State of California to cause birth defects or other reproductive harm. Eyes Hold eyelids apart and flush thoroughly with water for 15 minutes. Skin Remove contaminated clothing. Wash skin thoroughly for 15 minutes with soap and water. Inhalation Remove to fresh air. Ingestion Do not induce vomiting. Dilute with water. Contact a physician. In all cases contact a physician immediately if symptoms persist. First Aid Handling and Storage Avoid direct contact. Wear personal protective equipment chemical resistant gogglesgloves clothing to prevent direct contact with skin and eyes. Use only in well ventilated areas. Open doors and windows during use. Use a properly fitted NIOSH respirator if ventilation is poor. Wash thoroughly with soap and water after use. Remove contaminated clothing and launder before reuse. Industrial Flooring Clean Up Clea

n brushes and spray equipment with water. Dried Sikagard 307 W can be removed with paint stripper cellulose thinners xylene or toluene. Use personal protective equipment chemical resistant gloves gogglesclothing. Without direct contact sweep up spilled or excess product and place in suitable sealed container. Dispose of excess product and container in accordance with applicable local state and federal regulations. Additional Info Technical Data Sheets are updated periodically. To ensure the most current version is being used visit Technical Resources on www.sikafloorusa.com. Proper material application is the responsibility of the user. Site visits made by Sika personnel are for making technical recommendations only and not for supervising or providing quality control. KEEP CONTAINER TIGHTLY CLOSED KEEP OUT OF REACH OF CHILDREN NOT FOR INTERNAL CONSUMPTION FOR INDUSTRIAL USE ONLY All information provided by Sika Corporation Sika concerning Sika products including but not limited to any recommendations and advice relating to the application and use of Sika products is given in good faith based on Sikas current experience and knowledge of its products when properly stored handled and applied under normal conditions in accordance with Sikas instructions. In practice the differences in materials substrates storage and handling conditions actual site conditions and other factors outside of Sikas control are such that Sika assumes no liability for the provision of such information advice recommendations or instructions related to its products nor shall any legal relationship be created by or arise from the provision of such information advice recommendations or instructions related to its products. The user of the Sika products must test the products for suitability for the intended application and purpose before proceeding with the full application of the products. Sika reserves the right to change the properties of its products without notice. All sales of Sika produ

cts are subject to its current terms and conditions of sale which are available at www.sikacorp.com or by calling 800-933-7452. Prior to each use of any Sika product the user must always read and follow the warnings and instructions on the products most current Technical Data Sheet product label and Material Safety Data Sheet which are available online at www.sikafloorusa.com or by calling Sikas Technical Service Department at 800-933-7452. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Technical Data Sheet product label and Material Safety Data Sheet prior to product use. Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Technical Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyers sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. No other warranties express or implied shall apply including any warranty of merchantability or fitness for a particular purpose. Sika shall not be liable under any legal theory for special or consequential damages. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. Visit our website at www.sikafloorusa.com 1-800-933-SIKA NATIONWIDE Regional Information and Sales Centers. For the location of your nearest Sika sales office contact your regional center. Sika Corporation Sika Canada Inc. Sika Mexicana S.A. de C.V. 201 Polito Avenue 601 Delmar Avenue Carretera Libre Celaya Km. 8.5 Lyndhurst NJ 07071 Pointe Claire Fracc. Industrial Balvanera Phone 800-933-7452 Quebec H9R 4A9 Corregidora Queretaro Fax 201-933-6225 Phone 514-697-2610 C.P. 76920 Fax 514-694-2792 Phone 52