Skip to content

IPS Corporation Weld-On® Plumbing Cements

Technical Specification ARYAPET A600 ARYAPET A600 is a Milky White polyester film suitable as an insulating material for rotating electrical machines. It has superior thermal properties as compared with normal polyester film. Sr. Properties No Unit Test Method Typical Value General 1 Micron Thickness Gauge 2 JBF Method 36 50 75 100 125 144 200 300 400 500 2 Yield M Kg JBF Method 19.8 14.3 9.5 7.14 5.71 3 Density gmcc ASTM D 1505 1.4 1.4 1.4 1.4 1.4 4 Water Absorption ASTM D 570 0.55 0.55 0.55 0.55 0.55 5 Oligomer Extraction JBF Method 1.3 1.3 1.3 1.3 1.3 6 Service Temp 0 JBF Method C -70 to 150 Mechanical MD Tensile 1 2 3 Strength at 2 Kgcm ASTM D 882 kpsi 2000 1900 1900 1800 1800 28.4 27.0 27.0 25.5 25.5 2100 2000 2000 1900 1900 29.8 28.4 28.4 27.0 27.0 100 100 110 110 120 break TD Elongation at MD break TD 100 100 100 100 110 Co-efficient of Static 0.40 0.40 0.40 0.45 0.45 0.45 0.40 0.40 0.40 0.40 1.4 1.4 1.4 1.4 1.4 0.4 0.4 0.4 0.4 0.4 friction ASTM D 882 -- ASTM D 1894 Dynamic Thermal 1 Shrinkage MD 1500 C30 TD 2 Melting Point 3 Specific Heat 250 C 4 Coeff of Thermal Expansion Between 200 C 250 C ASTM D 1204 0 C DSC 255 255 255 255 255 Calg0C - 0.32 0.32 0.32 0.32 0.32 0 1kcmcm C MD- 36 X 10 -6 - TD -36 X 10 -6 Optical 1 Haze ASTM D 1003 50 55 60 70 80 7.5 9.5 12.5 14.5 17 Electrical 1 Break Down Voltage 2 Surface Resistivity 3 Volume Resistivity RT KV ASTM D 149 12 Ohm ASTM D 257 10 Ohm cm ASTM D 257 1016 4 Dielectric Constant - ASTM D 150 2.6-3.7 Dissipation Factor 230 C 50 Hz 0.002 0 5 23 C 1 KHz 0.005 230 C 1 MHz 0.011 00 C 50 Hz 0 50 C 50 Hz -- IEC 250 0 0.004 0.0015 100 C 50 Hz 0.007 1500 C 50 Hz 0.006 Permittivity 230 C 50 Hz 3.26 0 6 23 C 1 KHz 3.24 230 C 1 KHz 3.21 00 C 50 Hz 0 50 C 50 Hz -- IEC 250 0 3.26 3.27 100 C 50 Hz 3.35 1500 C 50 Hz 3.65 Chemical Resistance 1 Dilute acids and Alkalis Good 2 Concentrated Alkalis Poor 3 Concentrated HCL Fair 4 Concentrated H2SO4 Poor 5 Greases Oils Fats Good 6 7 8 Organic Solvents Alcoho

ls Hydrocarbons Ketones Esters Chlorinated compounds Phenols Cresols Chlorinated phenols Good Fairly Good Poor MD Machine Direction TD Transverse Direction Storage Handling ARYA PET need to be stock ed In a closed warehouse should not exposed to the direct sun light or light sources Avoid extremes of humidity It is recommended to store below 40C in dry places The information given above is to the best of our knowledge and experience. Some of the properties can be changed as a result of suppliers efforts to improve upon the quality or production efficiency of the subject. The information is believed to be true and accurate and is not intended to violate any statutory condition or right of a third party. JBF RAK LLC makes no warranty express or implied as to the fitness of the product for any specific use or purpose. The above data is purely for readers consideration investigation and verification and should be read in conjunction with the conditions for sale or contract. Technical Specification ARYAPET A600 ARYAPET A600 is a Milky White polyester film suitable as an insulating material for rotating electrical machines. It has superior thermal properties as compared with normal polyester film. Sr. Properties No Unit Test Method Typical Value General Micron 190 225 250 300 350 760 900 1000 1200 1400 JBF Method 3.76 3.17 2.86 2.38 2.04 gmcc ASTM D 1505 1.4 1.4 1.4 1.4 1.4 Water Absorption ASTM D 570 0.55 0.55 0.55 0.55 0.55 5 Oligomer Extraction JBF Method 1.3 1.3 1.3 1.3 1.3 6 Service Temp 0 JBF Method 1 Thickness 2 Yield M2Kg 3 Density 4 Gauge C JBF Method -70 to 150 Mechanical 1 2 3 MD Tensile Strength at break TD Elongation at MD break TD Co-efficient of Static friction Dynamic Kgcm2 kpsi -- ASTM D 882 1800 1800 1800 1700 1700 25.5 25.5 25.5 24.2 24.2 1900 1900 1900 1800 1800 27.0 27.0 27.0 25.6 25.6 120 130 130 140 140 110 120 120 125 125 0.35 0.35 0.35 0.35 0.35 0.30 0.30 0.30 0.30 0.30 1.2 1.2 1.2 1.2 1.2 0.4 0.4 0.4 0.4 0.4 ASTM D 882 ASTM D 1894

Thermal 1 Shrinkage 0 150 C30 MD TD ASTM D 1204 0 C DSC 255 255 255 255 255 Specific Heat 250 C Calg0C - 0.32 0.32 0.32 0.32 0.32 Coeff of Thermal Expansion 1kcmc 3 Melting Point 4 5 Between 200 C 250 C m0C MD- 36 X 10 -6 - TD -36 X 10 -6 Optical 1 Haze ASTM D 1003 86 90 93 94 96 20 21 22 24 26 Electrical 1 Break Down Voltage 2 Surface Resistivity 3 Volume Resistivity RT KV ASTM D 149 12 Ohm ASTM D 257 10 Ohm cm ASTM D 257 1016 4 Dielectric Constant - ASTM D 150 2.6-3.7 Dissipation Factor 5 230 C 50 Hz 0.002 230 C 1 KHz 0.005 230 C 1 MHz 0.011 0 0 C 50 Hz 0 50 C 50 Hz -- IEC 250 0.004 0.0015 1000 C 50 Hz 0.007 1500 C 50 Hz 0.006 Permittivity 6 230 C 50 Hz 3.26 230 C 1 KHz 3.24 230 C 1 KHz 3.21 0 0 C 50 Hz 0 50 C 50 Hz -- IEC 250 3.26 3.27 1000 C 50 Hz 3.35 1500 C 50 Hz 3.65 Chemical Resistance 1 Dilute acids and Alkalis Good 2 Concentrated Alkalis Poor 3 Concentrated HCL Fair 4 Concentrated H2SO4 Poor 5 Greases Oils Fats Good 6 7 8 Organic Solvents Alcohols Hydrocarbons Ketones Esters Chlorinated compounds Phenols Cresols Chlorinated phenols Good Fairly Good Poor MD Machine Direction TD Transverse Direction Storage Handling ARYA PET need to be stock ed In a closed warehouse should not exposed to the direct sun light or light sources Avoid extremes of humidity It is recommended to store below 40C in dry places The information given above is to the best of our knowledge and experience. Some of the properties can be changed as a result of suppliers efforts to improve upon the quality or production efficiency of the subject. The information is believed to be true and accurate and is not intended to violate any statutory condition or right of a third party. JBF RAK LLC makes no warranty express or implied as to the fitness of the product for any specific use or purpose. The above data is purely for readers consideration investigation and verification and should be read in conjunction with the conditions for sale or contract.